steam flow meter
Vortex Flow meter
Fluid: Liquid, Gas, Steam
Not For:fluid with high viscosity
vortex flow meter is mainly used for measuring flow of industrial pipeline fluid, such as gas, liquid and steam, etc. It has little pressure loss, broad span range and high accuracy. It is not under influence of density, pressure, temperature and viscosity when measuring volumetric flow. It has no movable mechanical parts with high reliability and little maintenance.
SPECIFICATION Local Display: 15,20,25,32,40,50,65,80,100,125,150 4 lines LCD 200,250,300,350,400,450,500mm 8 digit flowrate Measuring Range: 8 digit Totalizer Steam - 1.6 to 540,000 Kg/Hr Current Output: Gas - 3 to 46,000 M3/Hr 4-20 mA (2 wire) Liquid - 0.3 to 4950 M3/Hr Load Material: 600 Stainless Steel 301 / 304 / 316 Pulse Output: Accuracy Liquid: Scale Pulse (3 wire) +/-0.7% value of reading Rating Gas & Steam 3 to 30VDC, 20mA Max. +/-1.0% value of reading Communication: Unit: RS485(MODBUS Protocol) m3/h,km3/h,l/min,kg/h,t/h Data Storage: Repeatability: Operation parameter and totalizer +/-0.2% value of reading figures are stored by EEPROM for more Process Connection: than 10 years Flange / Wafer Housing Material: Flange type Aluminum Alloy JIS 10K / JIS 20K / JIS 40K Cable Entry: ANSI 150# / ANSI 300# / ANSI 600# Standard :M20 Option:1/2"NPTF DIN PN 10 / PN 16 / PN25 / PN 40 Power supply: Wafer type 12-36 VDC DN40~DN250 Ni-MH Battery (3 years working Hours) without Temperature / Pressure Sensor KeyPad: Temperature: 4 internal keys for programming -40 ~ +280 oC (Standard) and display control -40 ~ +420 oC (Optional) Option: Ambient Temperature: Pressure Sensor -20 ~ +60 oC Pressure compensation Pressure: Signal output 78 Kg/cm2 (Max.) 0-30 mV DC (20 uA Power supply) Protection Class: Temperature Sensor IP 65 Temperature compensation Explosion Proof, Exd IIC T6 Signal Output Intrinsically Safe, Eex ia IIC T4 PT100 (3 wires)
Size:
Table 3 Flow scope(Liquid)
Caliber |
Flow scope(m3/h) |
25 |
1.6~13 |
40 |
3~30 |
50 |
5~40 |
80 |
13~130 |
100 |
20~200 |
150 |
45~450 |
200 |
80~800 |
250 |
125~1200 |
300 |
180~1800 |
The maximum flow speed of liquid should be lower than 7m/s, the standard liquid means the liquid at the temperature of t=20°C.P-0.1013MPa;ρ=998kg/m3. |
Table 4 Flow scope(Gas)
Caliber |
Flow scope(m3/h) |
25 |
9~60 |
40 |
20~160 |
50 |
45~300 |
80 |
80~600 |
100 |
120~1000 |
150 |
200~2000 |
200 |
400~4000 |
250 |
750~8000 |
300 |
1000~10000 |
The means the air under normal temperature and pressure, t=20°C.P-0.1013MPa;ρ=1.205kg/m3. |
Production line
Want to order vortex flowmeter click
Go to download catalogue and user manual