vortex flow meter
Vortex Flow meter
Fluid: Liquid, Gas, Steam
Not For:fluid with high viscosity
vortex flow meter is mainly used for measuring flow of industrial pipeline fluid, such as gas, liquid and steam, etc. It has little pressure loss, broad span range and high accuracy. It is not under influence of density, pressure, temperature and viscosity when measuring volumetric flow. It has no movable mechanical parts with high reliability and little maintenance.
SPECIFICATION |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Table 3 Flow scope(Liquid)
Caliber |
Flow scope(m3/h) |
25 |
1.6~13 |
40 |
3~30 |
50 |
5~40 |
80 |
13~130 |
100 |
20~200 |
150 |
45~450 |
200 |
80~800 |
250 |
125~1200 |
300 |
180~1800 |
The maximum flow speed of liquid should be lower than 7m/s, the standard liquid means the liquid at the temperature of t=20°C.P-0.1013MPa;ρ=998kg/m3. |
Table 4 Flow scope(Gas)
Caliber |
Flow scope(m3/h) |
25 |
9~60 |
40 |
20~160 |
50 |
45~300 |
80 |
80~600 |
100 |
120~1000 |
150 |
200~2000 |
200 |
400~4000 |
250 |
750~8000 |
300 |
1000~10000 |
The means the air under normal temperature and pressure, t=20°C.P-0.1013MPa;ρ=1.205kg/m3. |
Production line
Want to order vortex flowmeter click
Go to download catalogue and user manual